Features of the Fluke 789
Fluke 789 features that are also included in the Fluke 787
Safety Conformance
Meets 1000 Volt EN61010-1 CAT III standards and 600 Volt EN61010-1 CAT IV standards.
Measurement Function | |
V dc | Range and Resolution 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V Best Accuracy (% of reading + LSD) |
V ac (true-rms) | Range and Resolution 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V Best Accuracy (% of reading + LSD) |
mA dc | Range and Resolution 30.000 mA Best Accuracy (% of reading + LSD) |
A dc | Range and Resolution 1.000 A (0.440 A continuous) Best Accuracy (% of reading + LSD) |
A ac | Range and Resolution 1.000 A (0.440 A continuous) Best Accuracy (% of reading + LSD) |
Resistance | Range and Resolution 400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M Best Accuracy (% of reading + LSD) |
Frequency (0.5 Hz to 20 kHz) | Range and Resolution 199.99 Hz, 1999.9 Hz, 19.999 kHz Best Accuracy (% of reading + LSD) |
Diode Test | Range and Resolution 2.000 V (shows diode voltage drop) Best Accuracy (% of reading + LSD) |
Continuity | Range and Resolution Beeps for resistance < approx. 100 ohms |
Output Function | |
DC Current Output (Internal battery operation) |
Range and Resolution 0.000 to 20.000 mA or 4.000 to 20.000 mA (selectable at power-up) Over-range to 24.000 mA Drive Capability (% of span) Accuracy |
DC Current Simulate (Ext. 24 Volt loop supply) |
Range and Resolution 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA Drive Capability (% of span) Accuracy |
24 V Loop Supply | Range and Resolution Minimum 24 V Drive Capability (% of span) Accuracy |
Current Adjustment Modes | Range and Resolution Manual: 0.001 mA, 0.1 mA, 25 % and 100 % step Automatic: Slow Ramp, Fast Ramp, 25 % step |
General Specifications | |
Maximum voltage applied between any jack and earth ground: |
1000 V RMS |
Storage temperature: | -40 °C to 60 °C |
Operating temperature: | -20 °C to 55 °C |
Temperature coefficient: | 0.05 x (specified accuracy) per °C (for temperatures < 18 °C or > 28 °C) |
Relative humidity | 95 % up to 30 °C; 75 % up to 40 °C; 45 % up to 50 °C; 35 % up to 55 °C |
Vibration: | Random, 2 g, 5-500 Hz |
Shock: | 1 meter drop test |
Safety: | Designed in accordance with EN61010, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010..1-92 Over-voltage Category III |
Size: | 50 mm H x 100 mm W x 203 mm L (1.97 in H x 3.94 in W x 8.00 in L) |
Weight: | 600 g (1.3 lbs) |
Battery: | Four AA alkaline batteries |
Battery life: | 140 hours typical (measurement), 10 hours typical (sourcing 12 mA) |
Warranty: | 3 years |
No customer comments for the moment.