Power Analizers Flukes and Chauvin Arnoux

ApplicationsFluke 345Fluke 434Fluke 435Fluke 43BFluke 1735Fluke 1743Fluke 1744Fluke 1745Fluke VR1710
1-Phase/3-Phase•/-•/••/••/-•/••/••/••/••/-
Frontline Troubleshooting




Load study, PQ Survey


Compliance (EN50160)



Long-term Analysis


FeaturesFluke 345Fluke 434Fluke 435Fluke 43BFluke 1735Fluke 1743Fluke 1744Fluke 1745Fluke VR1710
DisplayColor GraphicalColor GraphicalColor GraphicalB&W GraphicalColor GraphicalLEDsLEDsLCD & LEDsLED
Voltage Channels144134442
Current Channels14414444
Included Current Probes2000 A40A/400A Clamps3000A Flexis40A/400A Clamps15A/150A/3000A Flexis15A/150A/3000A Flexis15A/150A/3000A Flexis15A/150A/3000A Flexis
Dust/Water ResistanceIP40IP51IP51IP51IP65²IP65IP65IP50IP40
Safety Rating600 V CAT IV600 V CAT IV/1000 V CAT III600 V CAT IV/1000 V CAT III600 V CAT III600 V CAT III600 V CAT III600 V CAT III600 V CAT III300 V CAT II
SoftwareFluke Power LogFluke ViewFluke Power Log/Fluke ViewFluke ViewFluke PowerLogFluke PQ LogFluke PQ LogFluke PQ LogFluke Power Log
Battery Operation (hours)24776.524

5
Recording CapabilityFluke 345Fluke 434Fluke 435Fluke 43BFluke 1735Fluke 1743Fluke 1744Fluke 1745Fluke VR1710
Typical Recording Period (days)173073090909030
Memory2 MB8 MB16 MB512 KB8 MB8 MB8 MB8 MB32 KB
Min/Max/AVG Logging
Flicker

Harmonics
Event Capture
Waveform Capture


User defined Logging



Powered off of measured signals




Sample rate9.6 kHz20.48 kHz20.48 kHz12.8 kHz / 15.36 kHz10.24 kHz10.24 kHz10.24 kHz10.24 kHz1/4 cycle
High-speed capture rate
200 kHz200 kHz25 MHz



100 µs
Peak Voltage1 kV6 kV6 kV1.25 kV




Analysis CapabilityFluke 345Fluke 434Fluke 435Fluke 43BFluke 1735Fluke 1743Fluke 1744Fluke 1745Fluke VR1710
Statistical Analysis (including EN50160)


Report Generator
Root Cause Analysis





AccuracyFluke 345Fluke 434Fluke 435Fluke 43BFluke 1735Fluke 1743Fluke 1744Fluke 1745Fluke VR1710
IEC 61000-4-30 Class A Compliant







Volts RMS
0.5% Vnom0.1% Vnom±(1%+10 counts)±(0.5%+10 counts)0.1% of range0.1% of range0.1% of range± 0.5% of range (300 V)
Current RMS (excluding clamp unless specified)
±(1%+5 counts)±(1%+5 counts)±(1%+10 counts)±(1%+10 counts)2% of range with flex CT2% of range with flex CT2% of range with flex CT
¹ (8 voltage channels without current)
² (except battery housing)
Applications Fluke 345 Fluke 434 Fluke 435 Fluke 43B Fluke 1735 Fluke 1743 Fluke 1744 Fluke 1745 Fluke VR1710
1-Phase/3-Phase •/- •/• •/• •/- •/• •/• •/• •/• •/-
Frontline Troubleshooting          
Load study, PQ Survey      
Compliance (EN50160)        
Long-term Analysis      
Features Fluke 345 Fluke 434 Fluke 435 Fluke 43B Fluke 1735 Fluke 1743 Fluke 1744 Fluke 1745 Fluke VR1710
Display Color Graphical Color Graphical Color Graphical B&W Graphical Color Graphical LEDs LEDs LCD & LEDs LED
Voltage Channels 1 4 4 1 3 4 4 4 2
Current Channels 1 4 4 1 4 4 4 4  
Included Current Probes 2000 A 40A/400A Clamps 3000A Flexis 40A/400A Clamps 15A/150A/3000A Flexis 15A/150A/3000A Flexis 15A/150A/3000A Flexis 15A/150A/3000A Flexis  
Dust/Water Resistance IP40 IP51 IP51 IP51 IP65² IP65 IP65 IP50 IP40
Safety Rating 600 V CAT IV 600 V CAT IV/1000 V CAT III 600 V CAT IV/1000 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 300 V CAT II
Software Fluke Power Log Fluke View Fluke Power Log/Fluke View Fluke View Fluke PowerLog Fluke PQ Log Fluke PQ Log Fluke PQ Log Fluke Power Log
Battery Operation (hours) 24 7 7 6.5 24     5  
Recording Capability Fluke 345 Fluke 434 Fluke 435 Fluke 43B Fluke 1735 Fluke 1743 Fluke 1744 Fluke 1745 Fluke VR1710
Typical Recording Period (days) 1 7 30 7 30 90 90 90 30
Memory 2 MB 8 MB 16 MB 512 KB 8 MB 8 MB 8 MB 8 MB 32 KB
Min/Max/AVG Logging
Flicker    
Harmonics  
Event Capture  
Waveform Capture      
User defined Logging        
Powered off of measured signals          
Sample rate 9.6 kHz 20.48 kHz 20.48 kHz 12.8 kHz / 15.36 kHz 10.24 kHz 10.24 kHz 10.24 kHz 10.24 kHz 1/4 cycle
High-speed capture rate   200 kHz 200 kHz 25 MHz         100 µs
Peak Voltage 1 kV 6 kV 6 kV 1.25 kV          
Analysis Capability Fluke 345 Fluke 434 Fluke 435 Fluke 43B Fluke 1735 Fluke 1743 Fluke 1744 Fluke 1745 Fluke VR1710
Statistical Analysis (including EN50160)      
Report Generator  
Root Cause Analysis            
Accuracy Fluke 345 Fluke 434 Fluke 435 Fluke 43B Fluke 1735 Fluke 1743 Fluke 1744 Fluke 1745 Fluke VR1710
IEC 61000-4-30 Class A Compliant                
Volts RMS   0.5% Vnom 0.1% Vnom ±(1%+10 counts) ±(0.5%+10 counts) 0.1% of range 0.1% of range 0.1% of range ± 0.5% of range (300 V)
Current RMS (excluding clamp unless specified)   ±(1%+5 counts) ±(1%+5 counts) ±(1%+10 counts) ±(1%+10 counts) 2% of range with flex CT 2% of range with flex CT 2% of range with flex CT  
¹ (8 voltage channels without current)
² (except battery housing)


No customer comments for the moment.