Fluke 1630 Earth Ground Clamp Meter

0,00 € tax incl.
Fluke
  • A wide ground loop resistance range, from 0.025 Ω to1500 Ω, to satisfy all requirements
  • Large jaw opening of 35 mm (1.38 in) for tests on ground conductors and/or equipotential bus bars
  • Measurement of ground leakage current, from 0.2 mA to 1000 mA, without needing to disconnect - ideal for system troubleshooting
  • Wide ac current measurement range from 0.2 A to 30 A allows one instrument for multiple applications
  • User-defined HI / LO Alarm limits, for rapid measurement evaluation
  • Handy ‘display hold’ button for capturing readings in hard-to-reach places
  • Time saving memory function automatically records and stores measured values
  • Automatic self calibration ensures correct measurement every time
  • Overload protection: 200 A
  • Carrying case and resistance test loop included
  • ≥ 8 hours battery life (continuous operation)
General Specifications
Operating error

Refers to the operating temperature range and is guaranteed for 2 years
Storage temp. range

-20 °C to 60 °C (-4°F to 140 °F)
Reference temp. range

23 °C ± 5 °C (73 °F ± 9 °F)
Storage humidity

<75 % Rh
Operating humidity

<85% Rh
Display

999 digital LC display with special symbols
Protection

IP30 according to IEC 529/EN 60529
Safety

300 V, CAT III pollution degree 2 IEC 61010-1 and IEC 61010-2-032
Weight

750 g (1.165 lbs)
Conductor size

35 mm (1.38 in) approximately
Dimension (length x width x depth)

276 mm x 100 mm x 47 mm (10.8 in x 3.9 in x 1.9 in)
Emission

IEC 1000 4-2, IEC 61326-I class B
Immunity

IEC 61000-4-2, 8 kV (air) criteria A

IEC 61000-4-3, 3 V/m performance criteria A
Range selection

Auto
Overload indicator

"OL" on display
Measuring time

0.5 sec
Measuring frequency

3.333 kHz
Battery type

9 V alkaline (type IEC 6 LR 61)
Battery life

≥ 8 hours (continuous operation)
Power consumption

40 mA
Low battery indication

Display symbol

Ground Loop Resistance (Autorange)
Range

Accuracy
(± % of reading Ω)
0.025 - 0.250 Ω

± 1.5 % rdg ± 0.02 Ω
0.250 - 9.999 Ω

± 1.5 % rdg ± 0.05 Ω
10.00 - 99.99 Ω

± 2.0 % rdg ± 0.3 Ω
100.0 - 199.9 Ω

± 3.0 % rdg ± 1.0 Ω
200.0 - 400.0 Ω

± 5.0 % rdg ± 5 Ω
400.0 - 600.0 Ω

± 10 % rdg ± 10 Ω
600.0 - 1500 Ω

± 20 %
Note:

Loop resistance with no inductance, external magnetic field < 50A/m, external electrical field < 1 V/m, conductor centered.



Earth Ground Clamp Meter
Includes:
  • Rugged carrying case with shoulder strap
  • Resistance test loop
  • 9 V battery
  • User's manual in English, French, Spanish, German, Italian, Portuguese, and Simplified Chinese